X2 series Multi-function safety relay 2 safety functions
Monitoring ofup to two different safety functions:
Potential-free signals
OSSD signals
Two-hand function
Function:
2 x Manual or automatic reset
2 x EDM (External Device Monitoring)
Safety contacts safety function 1:
2 x No contact DC13, 4A
Signal contacts safety function 1:
1 x Opener 24 VDC/1 A
Safety contacts safety function 2:
2 x Semiconductor output DC-13: 24 V / 2A
Signal contacts safety function 2:
1 x Semiconductor output 24 VDC / 100mA
General data
Type designation
Series X2
Item number
SP-K-70-001-03
Interference immunity
to EMC Directive
Mounting
standard DIN rail to EN 60715
Terminal designations
EN 60947-1
PFHD semi-conductor output
≤ 2.66 x 10⁻⁹ / h
PFDavg semi-conductor output
≤ 2.42 x 10⁻⁵
PFHD relay output
≤ 1.25 x 10⁻⁸ / h
PFDavg relay output
≤ 5.3 x 10⁻⁵
DC
high
Service life TM (EN ISO 13849-1)
20 Years
Safety data
Category (EN ISO 13849-1:2015)
Cat. 4
SIL (acc. IEC 62061)
suitable for applications in SIL 3
Approvals
IEC/EN 60204-1, EN 60947-5-1; EN ISO 13849-1, IEC/EN 62061, IEC 61508
CCF (ISO 13849-1)
> 65 points
Environmental conditions
Ambient temperature
–25 °C … +60 °C (non condensing) °C
Protection class
Enclosure: IP40, Terminals: IP20, Clearance: IP54
Max. storage temperature
–40 °C … +85 °C (non condensing) °C
Resistance to shock
30 g/11 ms
Resistance to vibrations to EN 60068-2-6
10 ... 55 Hz, Amplitude 0.35 mm
Altitude
max. 2,000 m
Contamination level
2
Electrical data
Rated operating voltage Ue
24 VDC / 24 VAC –20%/+20% V
Frequency range
50 Hz/60 Hz
Power Supply
SELV-Netzteil network as per DIN EN 60950; safety transformer as per DIN EN 61558-2-6 (AC); mains power supply must harmonise with device safety (characteristic/melting property) so that triggering is assured.
Power consuption
3.6 W (+ load of the safety outputs)
Protection of the operating voltage
we recommend a circuit breaker type Z (max. 16 A) or a fine fuse (max. 15 A. delayed action)
UL Rating of external fuse:
max. 16 A, only use fuses in accordance with UL 248 series
Isolation parameters acc. to IEC 60664-1
Rated insulation voltage Ui
- safety contacts
250 V
Safety outputs
50 V
Rated impulse withstand voltage Uimp
- safety contacts 13-14, 23-24
6 kV
-Safety outputs
0.8 kV
Overvoltage category
III
Pick-up delay
< 150 ms
Dropout delay emergency-stop
< 10 ms
Dropout delay power failure
< 10 ms
Bridging voltage drop
typ. 5 ms
Standby after power switched on [s]
< 1,5 s
Terminal blocks
Single-wire (rigid) or fine-wire (flexible)
0.2 … 2.5 mm²
Fine-wired with wire sleeve
0.25 … 2.5 mm²
0.5 Nm
Control current circuits/inputs
Inputs S12, S22
24 VDC/8 mA
Inputs X2, X3, X7
24 VDC/8 mA
Clock outputs S11, S21
> 20 VDC, 10 mA per output
Cable length
1500 m with 1.5 mm²; 2500 m with 2.5 mm²
Conduction resistance
max. 40 Ω
Relay outputs
Switching capacity of the safety contacts
contacts 13-14, 23-24, 33-34: max. 250 V, 6 A ohms. min. 10 VDC / 10 mA (Derating see 2.5)
Fuse rating of the safety contacts
external (Ik = 1000 A) acc. to EN 60947-5-1 Safety fuse 10 A quick blow. 6 A slow blow
Utilisation category to EN 60947-5-1
AC-15: 230 V / 4 A DC-13: 24 V / 4 A
Fuse rating for the auxiliary contact
41-42: 24 VDC / 1 A
Safety contact values
safety fuse 2.5 A quick blow, 2 A slow blow
Electrical service life (nominal load)
see 2.5 (operating manual) Years
mechanical lifespan
10 million switching cycles
Max. switching cycles / minute
20
Inductive consumers
provision is to be made for suitable protective wiring for suppression
Semi-conductor outputs
Switching capacity of the safety outputs Q
Qt1, Qt2: max. 2 A
Voltage drop
< 0.5 V
residual current
< 1 mA
Max. fuse rating of the safety outputs
refer to „Operating voltage“
Test impulse to Q1, Q2
< 1 ms (negativ), < 100 μs (positive)
Switching capacity of signaling outputs
semiconductor outputs Y1: 24 VDC/100 mA
Fuse rating of the signalling outputs
internal electronic trip, tripping current > 100 mA
Um den Download zu erhalten, geben Sie bitte Ihrer E-Mail-Adresse ein. Der Link wird Ihnen dann zugesendet.
Sie erhalten in Kürze eine E-Mail mit dem Download-Link.
Note on cookies
This website uses cookies to improve your user experience. If you wish to use our website, you agree to the use of cookies. You also have the option to decide which cookies should be set and which should not.
Essential
Session cookie
Functional
Google Maps
With this cookie you agree that Google Maps may be loaded.
Youtube
Hiermit werden Videos von Youtube (Google) eingebunden.